Hi guys,
Hope you all had a good break.
Insurance due for renewal on 31st March and email sent to Willie 6/2/22
Main engine parallel issue has been resolved
Starboard jet hyd leak has been fixed but port side jet is still leaking for now until maintenance get to it
Port main sump gasket has developed an oil leak as expected
-stbd main temp has been fluctuating a little bit, more so on the first run when the engines have been off for a few hours. It only really happened on one morning where the temp was 15 degrees lower than port after engines had warmed up for 10 mins then when under way it went into the 90’s. Since then both mains get to about 88 before the thermostat opens and they drop back to 83-84 (normal) worth keeping an eye on for now, been fine the last few day, for some reason that one day the thermostat was getting a bit stuck.
-apparently there is some scaffolding sticking out at the service wharf somewhere, keep an eye out! Aaron Mclean gave me the heads up.