Hi Nathan and Andy,
welcome home. Vessel on 24 hr ops, although day shift only as required. There has been quite a few day shift too, and probably will continue short term now that QCLNG had major power breakdown last night. May have adhoc day runs today, so have left SEACOCKS open and BATTERIES off.
apart from last night, night shifts have been fairly quiet with occasional adhoc runs. No Em call outs.
Refuelling vessel after each ship as normal.
Radar transmission not working, but data screen operational for convenience.
Couldn't turn spotlight last night, so please try to lubricate before calling maintenance. One Starboard engine room light not working (not bulb). MRF raised. AMSA survey completed. Grab bag torch only item I'm aware of. Batteries on order.
Sewage sensors have been known to stick on 'low'giving false readout, so monitor levels and pump frequently. ( Not sticking recently). Pumped this morning.
Had issue with Stb AC not stopping when stop button pressed. Repaired.
Have a great swing.
LT
GW