Welcome back,
Boat running well.
Lifejacket lights expire this month February, I notified maintenance and were waiting on new lights, see email,dated the 8th of February.
Notified maintenance about fire hoses as they expired last month ?.
Fire extinguishers are due this month, Maintenance are aware ?.
Come the 1st of March the vessel will be non compliant ?.
I bring this stuff up with maintenance and they seem to get upset and reply with, we are aware as we have a maintenance scheduled ?.
See flagged emails.
Mrf port side turbo cover cracked near brace.
Usual oil leaks on main engines, coolant leak on port main getting worse so monitor its progression.
Diva 8 has been working at cp3 and calls a no wash.
Rewrapped port exhaust with silver tape, there’s some on order to do starboard side ?.
Updated new maintenance number into phone.
Generator been getting up to 80 degrees the last couple of days, might just be the hot weather.
Cleaned strainers yesterday and Changed out all soaker pads.
Starboard main engine soaker pads I’ve been changing out two of them weekly, as there soaked through.
Changed out a few lines.
Extra run today for day shift on dataweb at 1315.
Have a good swing.