Be sure to keep a check on sump bolts.... Missing 2 on stb and 1 on port and most were loose, had oil exiting the sump and hitting the inboard side of engine room on stb room. Oil level was noticeably reduced within a 24hr period. Re tensioned bolts but still showing signs of oil residue on block and on surrounding soaker pads.
Genset vent fan played up, pulled connectors apart and cleaned them, working again but do keep an eye on em. Genset serviced by Shaun 23/9 New DVD is Onboard, have had the current one slip a few times, not enough to warrant a swap out yet. (DVD swapped out 3/10) Generator frequency fault on Genset. Ran all day fine then on 1115 run it have up halfway across, idle slowed frequency dropped and shutdown occurred. Suspect fuel/air issue but Shaun is getting onto it and MRF is lodged. Genset serviced by Shaun 06/10, found fuel filter was loose causing air leak and the issue of Genset shutting down, also cleaned the sea strainer. APLNG ERT replaced pads in vessels AED Shaun would like to replace 2 rocker covers at some time this swing, he is trying organise it through management. (Port #6 rocker cover is leaking 6/10) Careful if climbing under the dash, found stb fire alarm to eng room had been pulled out