Welcome back on swing !
> The fresh water leak in void 3 portside has been repaired but not fixed..........maintenance are aware. The positive is that it is not leaking as much !
> Only the big VHF unit is working , there is a MRF in place (MRF # 3541)
> Coolant leak on the exhaust manifold , Stb main outboard side fwd. MRF is in.
> There is fuel bug in the tanks , all filters were change 24th September, worth keeping an eye on ! Maintenance are aware of the problem and are planning to polish the fuel .
> There is a MRF in to repair the raw water leak and plumbing going into the secondary Genset raw water strainer.
> Seems to be a salt water hull/ exhaust leak in the port eng room , running down the aft outboard corner, not sure where it is coming from need to monitor. There is no MRF in as yet.
> The vessel has had a maintenance day up the creek the last 3 Sunday's hopefully this will continue for you.
> There is a tentative plan to slip the vessel on 22/23 October ........... See email from Ross Jacobs date 27th September.
> Defib is due for recalibration and pad change, spoke to Paramedic Ken, he tells me they are onto it .
Have a great swing , Ross & Baz