26/11 gps not showing AIS. Using sounder for SOG etc. voltage problem , had to reset.
port/starboard mains failed to start, had to parallel on several occasions. Had Brodie and electrician onboard, Inverter must stay turned on, or you lose CCTV. Suggested to run 2 days on port....2 days on starboard. Both chargers to be on Normal.
28/11 mon Genset raw water pump leaking. Replaced with onboard unit.
30/11 we'd. Genset raw water pump leaking. Replaced with 2nd onboard unit.....this one okay.
12/12. Vessel to slipway, 1200 hrs mains service.....valves.
freshwater and sullage gauges reset. Batteries load tested. Rudder bearings greased. Fm200 checked. New cabin door handles fitted. Fitted new toilet in female wc.
Genset raw water strainer box, barney busted and cleaned.
have a good swing.