be aware that the adblue bunkering fill station is filling up with water. The only way I think this is happening is from hose off.
there is a 4 lts container of genset coolant in the port void for topping up convenience.
Charts corrected to edition 1 of 2025. Was missing magenta pen so will have to rectify when possible. extra logs under dash
AP hazard cards and tag out tags in front of SDS folder
hand held spot light on board.
16/01 - 39deg day @ 1633 victron inverter shut down with over temperature alarm
N/S - couldn't cool ac void all night, temps stayed at above 45deg with only 2 aircons on and kept tripping both shore lead (thermal overload). Primary tripped on vessel and secondary tripped on shore.
19/01 @ 1017 hours
- 1000 hour servicing completed on port main (oil / fuel filters, valve and injector check and adjusted, replaced seawater pump impeller, anodes. Removed exhaust covers and found small exhaust leak on rear turbo. Will need to be monitored for leak after use
- 1000 hour service partly completed on starboard, no oil changed as oil was recently changed 250 hours ago, fuel filters replaced, sea water pump impeller, anodes but valve and injector adjustments couldn't be completed without barring tool which is on order. vessel will be stood down again to complete valve clearances, injector adjustments and may require further items actioned.
APLNG hazard card put in for CP3 port side too, under ramp rust. APLNG have looked at it and actioned it. Ramp getting stuck on lifting paint.
Run out of Adblue on std side only got 78 percent in no time to get more 20/01/25
Start banks may need load test as voltage is dropping to alarm point if fans are not turned off while sitting for extended time, or if they are started before mains in the morning before departing for first run. Still awaiting for auto shutoff / start to be implemented
CP1 is setting up equipment to begin pontoon removal process
AMSA operational inspections coming up, any deficiencies you know about or happen to find that should be rectified please follow up with management asap. Eg: MOB Proceedure etc....