-reset maintenance/cleaning lists (dataweb)
-pt genset 1000h service due.
-complete maintenance and cleaning lists (Dataweb)
-check and inspect all raw water lines for toilet system, filters + pumps, confirmed pump has failed, needs replacement ASAP MRF’d.
-aft lower saloon not working, cleaned all aircon filters, disinfected.
-condenser No.7 mounting bolts and washers have reacting metal causing rust and a lot of bleeds. MRF’d
-cleaned toilet vent fans.
-some damage to yellow arch ship ramp wheels MRF’d
-grease crane arm, grease nipples and anchor winch nipples, steering equipment lubed.
-align steering
-copied more leave forms, in check in desk ready for vessel- leave in cream folder in bookshelf of received.
-re-wired toilet raw water 24v back up pump into another switch as current use switched failed and would not turn off for vessel shut down.
-mrf yellow non slip to very top step of stairs leading to top deck. Have strip to glue down just need dry weather to glue it down.
-cleaned out and arranged clear spares and tools box.
-inspect all raw water strainers for all machinery. All clear. -clean both port amd strb main engine air filters.
vessel ready for service