-maintenance/cleaning lists completed (dataweb) created new lists
-monitor power supply issues, seems to be settling down. Maintained over 26volts entire time, no dock power supply issues, vessel stayed in charge all night and did not shut down.
-New crew Induction Sarah Beal
-run all fire pumps including roving pump.
-test all alarms on emergency panel in wheelhouse.
-clean out sea strainers for main engines and Genset raw water inlets.
-service anchor winch, grease brake, inspect all mounts secure, connections ok, chain stripper secured in place.
-emergency engine room fire drill conducted.
-refresh yellow marks on chain for anchor, first mark clip bridle on, second mark indicates correct amount slack in chain.
-clean out fresh water strainer at water tank and at galley sink tap.
-clean main saloon aircon filters.
-clean upper saloon aircon filters + disinfect.
-lube rudder posts.
-new crew training/inductions Tamsin Allan.
-tender bow ramp, fit new washes on hinge where needed spares left in clear box in fire locker.
-clean big red wine stain from port aft quarter near sea gate.
-top up sani-loo chlorine.
-clean vacuum filters.
-drink storage cupboard, fit/fabricated shelf edges/lips to stop drinks falling off shelf in seaways.
-fire drill on aft deck with roving fire pump.
-lube and service crane arm and nipples.
don't! need milk and ice 👌🏼 see you in the am
have a lovely night