18/06
-genset strb, coolant in genset reservoir is now clear, appears to be either mixing and diluting with sea water entering similar to the main engines or the coolant quality has completely deteriorated requiring a flush and coolant replacement.
-anchor winch collar had loose securing bolt requiring tightening and one of the counter sink end caps on collar righting clamp was loose and tightened which squashed it flat and outside of the keyway that keeps in position, I’ve bent it back in place and put it back inside the counter sunk end of the securing collar on winch break.
-18/06 Strb main engine seems to be loosing coolant I’ve topped up 750ml in the last 2 days I was on. Monitoring for further or consistent change. Has settled at a level today 20/06
-requested a new SAT phone SIM card from Gary.
-new fire extinguisher handle damaged from crane already need to make it clear to those using the crane to watch the cables closely.
-exhaust removed off port aft topsides near entrance gate
-New crew induction started for mikhala flint
-still need more “blue Chem” for sullage tank smell.
-run pt gender for a half day to circulate fluids and ensure it stills runs for emergency situations.
-complete weekly maintenance/cleaning lists
-back spliced a line in bow to stop un-ravelling
Need milk x 2, oat milk, Ice x 3
see you in the am! Have a lovely night mate