250 hour Mains serviced 16/5
New Genset, woohoo!! Installed on the 20/5. Basically the same as the previous generator, this one has no ECU so it has analog gauges which are in fahrenheit instead of degrees and PSI instead of BAR (American) as long as there is consistency it doesn’t really matter, I find it much better to do the readings than scrolling through the ecu!
MRF submitted for port main coolant leak and port main raw water leak.
All strainers scrubbed out and vacced out on the 20/5
vessel scrubbed both sides, inside and aft deck.. just normal handover clean etc 23/5
After the last audit we have to sign on to a heap of JSA’s (risk assessments) all of section 6 and section 7, best off speaking Des about the process.
Have a great swing.
Liam