Hi jag and crew
hope you had a good swing off
-belt on port fire pump tightened, all ok, good water through port fire pump.
-Found fuel leak port side aft engine at the fittings under to fire pump Brodie tightened and I left a pad under the fittings to ensure there are no more leaks. -fuel leak port side on fitting on fuel return line at the bulkhead has been MRFd
-and also asked to double check fuel leak under port fire pump as I believe there is still a leak there
-Cleaned up all soaker pads in port engine rooms behind generator, hydraulic leak is no more. I think it was left over from the boys when they fitted engines.
-fuel full, water full, Sullage empty.
- fixed light globe cover in port jet room.
-changed a couple of Globes around the boat.
- viabration still in engines boys are waiting for computer to get fixed to dial up harmonics.
-cleaned soaker pads out of both jet rooms nothing major down there
-cleaned up soaker pad and bolts from under STB generator not sure where all the bolts came from.
-black clip on shore power lost I have put in a MRF and it got declined see if you or Ross could chase one down as shore power cap won't close.
-Engines are running nice besides the viabration, we have been leaving engine room fans on for about 10 or so minutes as we had the STB fire alarm go off a couple of time when shut off too early.
-didn't have fireflap drop on us at all this swing so we are thinking that they might not have been set properly when they dropped on you guys,
-no oil for mains engines on the boat yet
- I gave the engines and generators a nice coat of lanox they came up nice and shiny be careful as they maybe a bit slippery
im pretty sure I've covered everything, give me a call if you need anything,
ps we done weeklys, 2 weeklys, monthly's on sunrise so expect to go on there at some stage to keep them up to date.
Cheers
Ryan, Annemaree and crew