1) STBD side kaMeWa jet hydrolic oil coolers cleaned and flushed out with new oil. Port side oil also flushed out. All four tanks are half filled and Shaun(engineer ) wants keep them half filled.
2) Stbd aft main had communication issue with throttle and it is fixed. Working good now.
3) All maintenance reports are done up to date.
4) Main cabin aft section port fwd Aircon unit was iced up on Sunday. But since then working good. MRF sent. Brodie knows this.
5) New set of wiper blades ordered .
6) Door retaining latch near stbd E/R is no good and new latch has been ordered.
7) All mains and machineries running well. Both port and stbd fwd mains cooling temperatures are between 80 - 85 deg: at rpm 1950- 2000. Brodie aware of this and due coolers clean up. Pse monitor temp and if it exceed 86 deg inform Brodie.
8) MRF has been initiated for wheel house door.
9) MRF has been raised for port genset cooling flow fault at the start up.
Give me a call. If need any info.
Have a nice swing.
Cheers
Jag